A buyer receives two quotations for a 5-function electric hospital bed. Both products have four medical casters. Both beds can be moved. Both suppliers describe their products as suitable for hospital use. But one quotation states: Central locking caster system. The other states: Individual caster brakes. These are not the same mobility configuration. The difference is not simply the number or diameter of the wheels. It affects how the bed is locked, released and maneuvered according to the design of the system. For buyers comparing an electric hospital bed, the caster specification should therefore answer several questions: Caster Type → Caster Diameter → Brake System → Pedal Arrangement → Central Locking Function → Steering Function Where Applicable. This guide explains how hospital buyers, medical equipment distributors and importers can verify these details before approving a sample or placing a bulk order. On a hospital bed equipped with an appropriate central locking system, the caster and brake arrangement is designed so that a control pedal or linked mechanism can change the operating state of multiple casters according to the system design. With individual caster brakes, the operator generally needs to engage or release the applicable brake at each caster separately. The user interacts with the linked brake system rather than treating each caster as a completely independent brake point. What the operator sees may be a pedal near the head or foot end of the bed. Depending on the design, it can involve: Do not describe a bed as centrally locked simply because a pedal is visible in a photograph. Many hospital beds use four casters, but their design can differ considerably. Two casters with the same nominal diameter can have different structures and functions. For example: Caster diameter: manufacturer specification. Brake system: central locking. Directional lock: confirm whether included. In this configuration, the applicable caster has its own braking mechanism. Its suitability depends on the product design and project requirement. The buyer should determine which brake system the hospital project requires. If the specification requires central locking, a bed with individual caster brakes should not be represented as the same configuration. The exact mechanical architecture depends on the caster system and bed design. Different hospital bed designs may place operating pedals in different positions. This makes it easier to understand where the operator accesses the brake control. A photograph alone may not explain what a pedal controls. Then show the resulting caster or brake state. Depending on the specific caster system, the pedal may control more than simple lock and release. Ask the manufacturer to confirm the exact system used on the quoted bed. This helps a bed maneuver in different directions. When engaged according to the system design, the relevant caster is controlled to support more directional movement. A brake state is intended to secure the bed according to its designed system. If the bed provides both functions, record them separately. Depending on the specific system, certain casters may include functions that others do not. A simple diagram can identify: Depending on the bed design, control pedals may be accessible from one or more locations. This can be done with: The finished hospital bed includes its platform, headboard, footboard, side rails and other specified components. This is more representative than looking at the caster component separately. Ask the supplier to demonstrate the exact hospital bed model being quoted. Different models may use different caster systems. Buyers often focus on backrest, leg, height and tilt movements. A photograph can show its appearance. This gives buyers a better understanding of the complete caster and brake system. This description is too broad for a project where brake type matters. Caster size: confirmed model specification. Brake configuration: central locking system. Directional lock: included or not included according to final configuration. Pedal arrangement: confirmed according to approved model. A different caster may affect mounting, bed height, mobility behavior and brake-system compatibility. If the approved sample uses one central locking caster system, the production order should follow the agreed configuration unless an authorized change is made. Changing caster dimensions or mounting arrangements can affect the complete bed geometry. Do not assume the original height specification remains unchanged. The function count describes the adjustable movements of the bed. Bed functions: required electric movements. Casters: required diameter and configuration. Brake system: central locking or other specified configuration. Directional lock: required or not required. A 5-function electric hospital bed generally refers to its adjustable bed movements. One model may use central locking casters. Another may use a different brake arrangement. The caster brake system belongs to the mobility architecture. A central locking caster system can use a mechanical linked control arrangement depending on the bed design. The bed may use electric actuators for positioning while the caster brake system uses mechanical operation. Buyers should not make assumptions based only on the term “central locking.” Which casters are affected? What happens in the brake position? What happens in the neutral position? Is there a directional position? In this state, the bed can be maneuvered according to the design of the caster system. Different caster manufacturers and bed designs may use different control arrangements. Moving it through corridors and around corners requires controlled caster behavior. But the buyer should verify whether the exact bed provides that feature. Central locking can provide a coordinated brake-control workflow. Buyers should consider: The complete configuration can involve casters, linkages, pedals and related structural components. If one supplier quotes central locking and another quotes individual brakes, the two offers should not be treated as identical configurations. A hospital tender may define mobility requirements in more detail. The actual tender response should correspond to the exact product being offered. This is especially important for hospital project procurement. Avoid vague claims such as: “Advanced wheels.” For example: Medical casters with central locking system. Do not combine several functions into one undefined phrase. Especially when the buyer has defined component requirements or long-term replacement planning. Confirm compatibility with the complete hospital bed. First confirm that the production beds use the agreed caster and brake configuration. A replacement caster may look almost identical but differ in mounting, brake interface or directional function. For replacement and after-sales service, confirm the component with the manufacturer or qualified supplier. The first objective is to understand how the system is supported. Especially for overseas distributors managing installed hospital beds. A technical datasheet can identify the specification. A sample can provide direct product verification. Specification → Photo → Video → Sample Verification → Final Production Requirement. An electric hospital bed is not defined only by its motors and adjustable functions. Its mobility system is another important technical layer. For professional buyers, the correct comparison is not: “Does the bed have wheels?” It is: What Casters → What Diameter → What Brake Architecture → What Pedal Arrangement → What Operating States → Is Directional Lock Included → Has the Exact System Been Verified? This distinction is especially important when comparing electric 5-function hospital beds for hospital projects, tenders and distributor product ranges. A bed with four individual caster brakes and a bed with a coordinated central locking system should not be treated as technically identical simply because both products have four wheels. Hebei Heyuan Medical Equipment Co., Ltd. manufactures electric 5-function hospital beds, electric 3-function hospital beds, ICU hospital beds, manual hospital beds and related medical furniture for international distributors and healthcare projects. Buyers can review our electric hospital bed range for different functional, caster and brake configurations. For central locking hospital bed specifications, electric hospital bed configurations, OEM and ODM requirements or bulk quotations, please contact Heyuan Medical with your required functions, quantity and destination market.“Central Locking Casters” Is Not Just a Wheel Specification
What Is a Hospital Bed Central Locking System?
The Basic Principle Is Coordinated Brake Control
This Is Different From Locking Every Caster Individually
Central Locking Changes the Operating Workflow
The exact operation depends on the caster and brake system used on the specific bed
Central Locking Does Not Mean the Bed Has Only One Brake Component
The Pedal Is Only the User Interface
But the Complete System Includes More Than the Pedal
Buyers Should Evaluate the Complete System
The function should be demonstrated and confirmed
1. Start by Confirming the Number and Type of Casters
Four Casters Does Not Describe the Complete Mobility System
Ask for the Exact Caster Specification
This Can Include
Do not compare hospital bed casters by diameter alone
Why Caster Diameter Is Only One Specification
A Larger Number Does Not Explain How the Caster Operates
The Brake System May Also Be Completely Different
For Procurement, Record Diameter and Function Separately
This creates a clearer technical specification
2. Understand Individual Caster Brakes
Individual Brakes Are a Simpler Operating Arrangement
The Operator Engages the Required Brake at the Wheel
This Configuration Can Be Used on Different Hospital Bed Models
Individual brakes should not automatically be described as inferior
Individual Brakes and Central Locking Serve Different Product Configurations
The Procurement Question Is Not Simply Which One Sounds More Advanced
Then Verify That the Offered Product Actually Uses That System
This Is Especially Important in Tender Procurement
Record the difference clearly
3. Understand Central Locking Casters
A Central System Coordinates the Mobility Controls
From the Buyer's Perspective, Focus on the Functional Result
Ask the Manufacturer to Demonstrate
Do not infer these functions from the words “central brake” alone
4. Check Where the Central Brake Pedals Are Located
Pedal Position Is Part of the User Interface
Buyers Should Look at the Exact Quoted Model
Ask for Clear Photographs From Both Ends and Both Sides
Catalogue beauty shots may not show the pedal clearly
Do Not Assume Every Visible Pedal Has the Same Function
Hospital Beds Can Have Different Foot-Operated Components
Ask the Supplier to Label It in the Technical Image or Video
A Useful Demonstration Should Show the Pedal Being Operated
Function demonstration is more reliable than visual assumption
5. Ask Whether the System Has Multiple Pedal Positions
Some Central Locking Systems Can Use Different Operating States
A Directional or Steering Mode May Also Be Available
Do Not Assume This Function Exists on Every Central Brake System
Central locking and directional locking are related but not identical specifications
6. What Is a Directional-Lock or Steering Function?
A Swivel Caster Can Rotate Around Its Vertical Axis
But During Longer Straight-Line Movement, Unrestricted Swiveling Can Affect Steering Behavior
Some Caster Systems Therefore Include a Directional-Lock Function
The exact configuration varies by manufacturer and caster system
Directional Lock Is Not the Same as the Main Brake
This Distinction Is Important
A Directional-Lock State Serves a Different Mobility Function
Do Not Describe Both as “Brake” in the Specification
Precise terminology helps buyers compare products correctly
7. Do Not Assume All Four Casters Perform the Same Function
A Central Locking System Can Use Different Caster Roles
This Is Particularly Relevant to Directional Control
Ask the Manufacturer for the Caster Layout
A layout drawing can be more useful than four identical-looking product photos
8. Check Whether the Brake Can Be Operated From More Than One Position
Accessibility Matters in Hospital Workflow
Do Not Assume a Pedal at One End Means the Same Control Is Available Everywhere
Ask the Supplier to Show the Actual Arrangement
The exact configuration should be recorded before ordering
9. Check the Brake System With the Bed in the Complete Configuration
Do Not Test Only an Empty Chassis
Where Appropriate, Evaluate the Complete Product
The Buyer Should Understand How the Finished Bed Moves and Locks
The caster system belongs to the complete hospital bed
10. Ask for an Unedited Caster and Brake Demonstration Video
A Short Video Can Clarify the System Quickly
The Video Can Show
Ask for the Original Product Rather Than a Similar Model
Model-specific verification reduces procurement ambiguity
11. Verify the Caster System During Sample Approval
Do Not Approve an Electric Hospital Bed Sample by Testing Only the Motors
The Mobility System Deserves Its Own Check
During Sample Evaluation, Confirm
Follow the manufacturer's operating instructions during testing
Push the Sample Bed — Do Not Just Look at It
A Caster Is a Functional Component
It Cannot Fully Demonstrate Mobility Behavior
Operate the Bed According to the Intended Method
Functional components should receive functional verification
12. Include the Brake Configuration in the Approved Specification
Do Not Record Only “Medical Casters”
Use a More Complete Specification
For Example
This creates a stronger reference for production
13. Do Not Let a Caster Substitution Become an Uncontrolled Production Change
Casters Are Not Purely Cosmetic Components
Changes Should Therefore Be Evaluated Before Production Substitution
For a Bulk Order, Confirm Critical Components
Component substitution should be controlled, not assumed
14. Caster Changes Can Affect Bed Height
The Caster Sits Between the Chassis and the Floor
This Can Matter When the Project Has a Defined Height Range
Reconfirm Relevant Dimensions After Major Caster Changes
Technical specifications are connected to each other
15. Central Locking Should Be Included in the RFQ When It Is Required
Do Not Write Only “5-Function Electric Hospital Bed”
It Does Not Automatically Define the Caster System
A Better RFQ Separates the Requirements
This prevents suppliers from filling in missing specifications differently
Central Locking Is Not One of the “Five Functions”
This Is an Important Technical Distinction
The Caster Brake System Is a Separate Product Feature
Therefore a Bed Can Have Five Electric Functions and Different Brake Configurations
Do not calculate brake features as part of the electric function count
Central Brake Is Also Different From the Electric Control System
The Handset or Nurse Control Panel Operates Electric Bed Functions
These Should Be Specified Separately
A Product Specification Can Therefore Have Separate Sections for
This creates a clearer technical hierarchy
Does Central Locking Require Electricity?
Do Not Assume “Central” Means “Electric”
The Exact Architecture Should Be Confirmed With the Manufacturer
Electric Bed and Electric Brake Are Not the Same Concept
Use accurate terminology in technical documents
Does Central Locking Mean All Four Casters Cannot Move?
The Exact Locked State Depends on the Caster System
Ask the Manufacturer to Explain and Demonstrate the Specific System
The Procurement Objective Is to Understand the Actual Functional Result
Specific questions are better than generic assumptions
What Does Neutral Mean on a Hospital Bed Caster System?
Some Systems Include a Free-Movement State
The Exact Pedal Position and Function Depend on the Product
Do Not Publish a Universal Pedal Diagram Unless It Matches the Actual Bed
Use the instructions for the exact model
Why Steering Behavior Matters on a Hospital Bed
A Hospital Bed Is Larger Than a Typical Mobile Cart
Different Caster Modes Can Influence Maneuverability
This Is Why Some Systems Include Directional Control
Do not advertise a steering function unless it is actually included
Central Locking vs Individual Brakes: Which Should Buyers Choose?
The Answer Depends on the Project Specification
Individual Brakes Use a Different operating method
Neither Configuration Should Be Selected Only From a Marketing Label
The correct configuration is the one that meets the defined project requirement
Do Not Compare the Two Systems by Price Alone
A Central Locking System Adds More Than a Different Caster
This Can Affect the Product Cost
Normalize the Bed Specification Before Comparing Quotations
Compare like with like
What Should Buyers Check in a Tender Specification?
Look for More Than the Words “Four Casters”
Extract Each Requirement Separately
For Example
Then ask the supplier to respond line by line
Do Not Mark “Comply” Until the Exact System Is Confirmed
A Catalogue May Use General Language
If the Supplier Needs Clarification, Keep the Item Open
A Clear Deviation Is Better Than a False Compliance Statement
Technical transparency reduces problems later in the project
How Should Distributors Present Central Locking in a Product Catalogue?
Use Specific Language
Describe the Actual Configuration Instead
If Directional Lock Is Included, Identify It Separately
Clear specifications help overseas buyers compare products
Should Buyers Ask for the Caster Brand?
Component Identification Can Be Useful for Some Projects
But Brand Name Alone Does Not Replace Technical Verification
Ask for the Relevant Specification
A recognizable component name is not a substitute for an approved system configuration
How Should Central Locking Be Checked During Bulk Inspection?
The Inspection Should Refer Back to the Approved Specification
Then Follow the Defined Inspection Process
Relevant Checks Can Include
Inspection should verify the approved product rather than create a new requirement
Do Not Replace Central Locking Casters With Visually Similar Casters Without Confirmation
Appearance Does Not Prove Compatibility
The Linked System Makes Compatibility Particularly Important
Use the Correct Part Identification
Do not select replacement casters by diameter and appearance alone
Ask About Spare-Part Identification Before the Bulk Order
This Does Not Mean the Buyer Needs to Purchase a Large Spare Inventory Immediately
Ask Whether the Manufacturer Can Identify
This Can Make Future After-Sales Communication Easier
Technical support begins with correct component identification
Electric Hospital Bed Central Locking System Checklist
Before Ordering, Confirm These 12 Points
These questions turn “central locking casters” into a verifiable technical specification
What Evidence Should Buyers Request?
Use More Than One Type of Product Information
A Photograph Can Show the Hardware Arrangement
A Video Can Demonstrate the Function
Different evidence answers different questions
For Important Projects, Combine Them
This provides a stronger technical trail than relying on a catalogue sentence alone
Central Locking Is a Separate Technical System Within the Electric Hospital Bed